Tipsa dina vänner om produkten:
Development and Verification of a Linear-fit Mixed System Rating Method for Unitary Two-speed and Variable-speed Air Conditioners Nist
Beställningsvara
Julklappar kan bytas fram till 31:e januari
Development and Verification of a Linear-fit Mixed System Rating Method for Unitary Two-speed and Variable-speed Air Conditioners
Nist
A linear-fit method of rating residential-type air conditioning systems was evaluated based on performance predictions and laboratory testing of one two-speed matched system and two mixed systems (matched two-speed condensing unit, matched indoor coil blower, and two mixed coil blowers). The individual evaporators and the condensing unit were separately tested using water heated/cooled condensing/evaporating units at standard air conditions over a range of evaporator refrigerant saturation temperatures, evaporator superheats, and liquid refrigerant temperatures. Capacity predictions were within ±1.0 % of the tested values for the mixed systems, and the EER predictions were within ±1.5 % of the measured EERs. The methods used for system rating on the two-speed system can also be applied to a variable-speed system.
| Media | Böcker Pocketbok (Bok med mjukt omslag och limmad rygg) |
| Releasedatum | 17 mars 2014 |
| ISBN13 | 9781497334786 |
| Utgivare | CreateSpace Independent Publishing Platf |
| Antal sidor | 98 |
| Mått | 216 × 279 × 5 mm · 254 g |
| Språk | Engelska |